Composition of Walls, Floors and Ceilings

ROOF 1

  • Smooth groove covering made of galvanized steel 0,6 mm sheet treated with special polyester varnish protective layers.
  • Lathing 60/40 mm
  • Counter lath 100/50
  • safety diffusion waterproof 3-layer foil made of firm combination of polypropylene fabric and a waterproof film placed in between them
  • Supporting truss roof structure – upper truss belt.
  • Space
  • Supporting truss roof structure – lower truss belt.
  • PU foam thk. 240 mm λD = 0,12 W/mK/
  • Bottom wire fixation
  • A vapour control barrier made of waterproof, reinforcement grid, attached by means of a double-sided adhesive tape
  • Structural CD profile, height: 50 mm
  • Protective suspended gypsum board ceiling using the FERMACELL board / λR = 0,32 W/mK/, thickness of 12,5 mm, anchored on hinges.

ROOF 2

  • Ceramic or concrete roofing
  • Wooden lating 60/40
  • Counter lath 100/50
  • Safety diffusion waterproof 3-layer foil made of firm combination of polypropylene
  • waterproof film placed in between them
  • Supporting truss roof structure – upper truss belt.
  • Space
  • Supporting truss roof structure – lower truss belt.
  • PU foam thk. 240 mm λD = 0,12 W/mK/
  • Bottom wire fixation
  • A vapour control barrier made of waterproof, non-corrosive aluminium layer placed between a highly transparent polyester foil and a polyethylene foil with a reinforcement grid, attached by means of a double-sided adhesive tape
  • Structural CD profile, height: 50 mm
  • Protective suspended gypsum board ceiling using the FERMACELL board / λR = 0,32 W/mK/, thickness of 12,5 mm, anchored on hinges

EXTERIOR WALL

  • Thin mineral plaster coat, grain size: 1,5 mm
  • Contact insulation system using the EPS 100 stabilized self-extinguishing polystyrene, thickness 140 mm
  • Protective suspended gypsum board ceiling using the FERMACELL board / λR = 0,32 W/mK/, thickness of 12,5 mm, anchored on the metal bearing
  • IH structure
  • Metal spatial load-bearing structure of a building with PU foam thk. 240 mm λD = 0,1 W/mk/
  • A vapour control barrier made of waterproof, non-corrosive aluminium layer placed between a highly transparent polyester foil and a polyethylene foil with a reinforcement grid, attached by means of a double-sided adhesive tape
  • Protective suspended gypsum board ceiling using the FERMACELL board / λR = 0,32 W/mK/, thickness: 12,5 mm
  • Surface leveling and painting

INTERIOR WALL

  • Levelling
  • Protective suspended gypsum board ceiling using the FERMACELL board / λR = 0,32 W/mK/, thickness: 12,5 mm, anchored on the metal bearing building structure
  • Metal spatial load-bearing structure of a building with PU foam thk. 240 mm λD = 0,13 W/mK/
  • Protective suspended gypsum board ceiling using the FERMACELL board / λR = 0,32 W/mK/, thickness: 12,5 mm
  • Surface leveling and painting

FLOOR 1

  • Contact layer – ceramic tile with a friction coefficient of μ≥0,3
  • Flexible adhesive sealer with embedded glass fibre reinforcing mesh – thickness: 4,0 mm
  • Heating mat – thickness: 0,4 mm
  • F-board insulation panels – thickness: 10 mm
  • Flexible, cement based adhesive
  • Bonding primer
  • 2x Fermacell panel, thickness: 12,5 mm
  • Thermal unsulation with floor boards, total thk. 180 mm or PU foam (40-50 kg/m3) thk. 110 mm λD = 0,2 W/mK/
  • PE separation foils, overlaps are glued together, the foil reaches up the walls, thickness: 0,15 mm
  • C 16/20 (B 20), a load bearing reinforced concrete slab with 8/100-8/100 KARI mesh, thickness: 200 mm
  • Waterproofing + radon barrier, deposited in between the 300/300 g/m2/Filtek geotextile
  • Compacted buffer layer of sifted quarry material, fr. of 0-2 mm, thickness: 50 mm
  • Compacted gravel base, fr. of 16-32 mm, thickness: 300 m on unmade ground
  • Compacted excavated material whose modulus of deformation is min. 40 MPa
  • Original terrain

FLOOR 2

  • Contact layer – floating wooden floor
  • PE foil, thickness: 025 mm
  • Heating foil, thickness: 0,4 mm
  • Insulation, thickness: 3mm
  • 0,2 mm PE foil
  • 2x Fermacell panel, thickness: 12,5 mm
  • Thermal insulation with floor boards, total thk. 180 mm or PU foam (40-50 kg/m3) thk. 110 mm λD = 0,2 W/mK/
  • PE separation foils, overlaps are glued together, the foil reaches up the walls, thickness: 0,15 mm
  • C 16/20 (B 20), a load bearing reinforced concrete slab with 8/100-8/100 KARI mesh, thickness: 200 mm
  • Waterproofing + radon barrier, deposited in between the 300/300 g/m2/Filtek geotextile
  • Compacted buffer layer of sifted quarry material, fr. 0-2 mm, thickness: 50 mm
  • Compacted gravel base, fr. of 16-32 mm, thickness: 300 mm on unmade ground
  • Compacted excavated material whose modulus of deformation is min. 40 MPa
  • Original terrain